Spatially and temporally resolved IR-DFWM measurement of HCN released from gasification of biomass pellets

Dina Hot et al., Proceedings of the Combustion Institute 37, pp. 1337 – 1344 (2019)
Spatially and temporally resolved IR-DFWM measurement of HCN released from gasification of biomass pellets using NLIR technology as featured in Proceedings of the Combustion Institute, 2019

Nonintrusive Mid-IR DFWM measurement of HCN released during biomass gasification

For the first time, to the best of the authors’ knowledge, nonintrusive quantitative measurement of hydrogen cyanide (HCN) released during the devolatilization phase of straw pellets gasification is demonstrated with high spatial and temporal resolution. Mid-infrared degenerate four-wave mixing (IR-DFWM) measurements of HCN were performed by probing the interference-free P(20) line in the v1 vibrational band at around 3 µm and the IR-DFWM signal was detected with an upconversion-based detector, providing discrimination of thermal noise and increased sensitivity. A novel single-pellet setup consisting of a multi-jet burner was used to provide hot flue gas environments with an even and well-defined temperature distribution, for single straw pellet gasification at atmospheric pressure. The environments had temperatures of 1380 K, 1540 K and 1630 K with a constant oxygen concentration of 0.5 vol%. In order to quantify the amount of HCN released during the devolatilization of straw pellets, calibration measurements were performed in well-defined HCN gas flows. Selected hot water lines were probed with IR-DFWM in the interrogated volume to obtain the instantaneous temperature, which were used to correct the temperature effect. HCN concentrations up to 1500 ppm were detected during the devolatilization stage, and the results indicate a strong temperature dependence of the HCN release.

Explore Spectroscopy news with NLIR

Would you like to learn more?

Are you interested in multi-component gas analysis with mid-infrared spectroscopy? Discover how NLIR’s mid-infrared spectrometers can enable your research as well as industrial application.

Related News

Upconversion-based mid-infrared spectrometer using intra-cavity LiNbO3 crystals with chirped poling structure using Nlir technology as in Optics Letters, 2019

Upconversion-based mid-infrared spectrometer using intra-cavity LiNbO₃ crystals with chirped poling structure

Søren M. M. Friis et al., Optics Letters 44, pp. 4231 – 4234 (2019)
More information
Time-resolved mid-infrared photoluminescence spectroscopy of an undoped InAs substrate using NLIR spectrometer as featured in Applied Physics Letters

Time-resolved mid-infrared photoluminescence spectroscopy of an undoped InAs substrate

Hisashi Sumikura et al., Applied Physics Letter 124, 052105 (2024)
More information
Low-noise mid-IR upconversion detector for improved IR-degenerate four-wave mixing gas sensing using NLIR technology as in Optics Letters, 2014

Low-noise mid-IR upconversion detector for improved IR-degenerate four-wave mixing gas sensing

Lasse Høgstedt et al., Optics Letters 39, pp. 5321 – 5324 (2014)
More information

Related Scientific Research

Stay up-to-date

Sign up to our newsletter to stay up to date with the latest NLIR news!

RD engineer interested in the latest mid-infrared spectrometer news